2016年沃尔玛ES验厂新规(三)
2018-01-07 13:47 作者:admin
2016年沃尔玛ES验厂新规(三):
21&22:Facility emergency exit doors:
Are obstructed;
Are locked;
Do not have a landing with at least 1 meter (3 feet) before beginning of first step.
应急逃生门不应被堵塞,上锁。
Facility emergency exit doors:
Are not side-hinged doors;
Do not open in the direction of travel with a single motion;
Do not close automatically when leading to a staircase.
Are not operable.
应急逃生门应带有铰链,并且能一个动作超一个方向推开,可以自动关闭。
23:Facility emergency exit windows:
Are obstructed;
Are locked;
Do not have a landing on the exit side.
24:Facility emergency fire alarms:
Are not present at the facility;
Are not present in areas of the building not occupied by the facility;
Have error indicators on the fire alarm control panel.
消防警铃显示正常状态。
25&26:Facility emergency fire alarms:
Are not audible;
Do not have beacon or flashing lights in high-noise areas.
消防警铃应可以清楚的带车间每个角落听到, 超过9db的车间需安装指示灯。
Facility emergency fire alarms:
Are not connected to a secondary power source;
Are not inspected every month.
消防警铃应每月检查,并且有第二电源。
27:Facility:
Does not have a sprinkler system;
Does not have a control panel set to “AUTOMATIC” if there is a fire pump available;
Does not have a fire hydrant system.
超过23米的建筑或面积超过75平米及人员密集的区域 必须安装自动喷淋系统或消防栓。
28 Water supply for sprinkler or fire hydrant system:
Is not stored in a suction tank, elevated tank, or reservoir;
Is observed to be empty;
Is not monitored by a water level gauge;
Is not inspected every month for sufficiency.
给水系统。
29:Inspections of sprinklers or fire hydrants:
Are not conducted every three months by facility staff;
Are not conducted every year by an approved third party;
Are not documented.
自动喷淋或消火栓每三个月检查一次,每年由第三方检查一次,保存报告和记录。
3:Excessive amounts of flammable liquids are stored on production floor rather than in the flammable liquid storage room.
生产现场不应存有过多的易燃易爆物品。

- 上一篇:什么是SCS验厂